内窥镜设备送水送气不顺畅是怎么回事?

来源:http://www.jiangrenyiliao.cn/ 发布时间:2022-04-16 浏览量:0

  内窥镜设备如今在医疗行业中频繁的应用,使用时间久了自然而然的会出现一些小问题,比如说突然出现了设备送水送气不顺畅了,那么这是怎么回事呢?下面来讲讲吧。
  Endoscope equipment is now frequently used in the medical industry. After a long time of use, there will naturally be some small problems, such as the sudden emergence of the equipment to send water and air is not smooth, so what is going on? So let's talk about it.
  内窥镜设备送水送气不顺畅的原因有几个,比如:水瓶接口的O型圈损坏、老化、丢失,将水倒入送风管。水瓶盖内的O型圈丢失或损坏,导致气体流出水平仪。除此之外,水太满或水瓶没有拧紧。主机气泵未开启,内窥镜与主机未按相应要求连接牢固,无法将空气输送内窥镜管路。内窥镜使用后不能及时床边清洗,或前内窥镜未及时彻底清洗,导致蛋白凝固。不合理的清洁保养造成供水、供气按钮损坏。
  There are several reasons why the water and air supply of endoscope equipment is not smooth, such as damage, aging and loss of the O-ring of the water bottle interface, and pouring water into the air supply pipe. The O-ring inside the bottle lid is missing or damaged, causing gas to flow out of the level. In addition, the water is too full or the bottle is not tightened. The air pump of the main machine is not opened, and the endoscope and the main machine are not firmly connected according to the corresponding requirements, so the air cannot be transported to the endoscope pipeline. The endoscope can not be cleaned bedside in time after use, or the endoscope is not cleaned thoroughly in time before disinfection, resulting in protein coagulation. Unreasonable cleaning and maintenance caused water supply and gas supply button damage.
  那针对原因,我们使用设备时应该要怎么处理?检查水瓶接口和水瓶盖内的O型圈,看是否损坏或丢失。如果出现相应的问题,需要及时更换。及时拧紧水瓶以免漏气,水瓶内的水不要太满,需要储存适量的空气。打开气泵,内窥镜与主机的连接需要稳定。如果送风按钮和供水按钮损坏,需要及时更换。内窥镜应用后,需要立即在床边进行清洁。清洗时,应将转炉与给水、供气管道一起清洗,管道的供气和供水应重复15秒。床头清洗完成后,需要立即发送设备,可以去室进行。
  So what should we do when we use the equipment for that reason? Check the bottle connector and o-ring inside the lid for damage or missing. If any problem occurs, replace it in time. Tighten the water bottle in time to avoid air leakage, the water in the bottle is not too full, need to store the right amount of air. Open the air pump, the connection between the endoscope and the host machine needs to be stable. If the air supply button and water supply button are damaged, replace them in time. Bedside cleaning is required immediately after endoscope application. When cleaning, the converter should be cleaned together with the water supply and gas supply pipeline, and the gas supply and water supply of the pipeline should be repeated for 15 seconds. After cleaning the head of the bed, it is necessary to send the equipment immediately and go to the disinfection room for disinfection.
  内窥镜设备维修事项也要提前做好工作才行,操作人员应该及时发现故障,通过系统分析,找出发生故障的原因,掌握排除故障的方法,恢复内窥镜设备的技术状态非常重要。
  Endoscopic equipment maintenance matters should also do a good job in advance, the operator should find out the fault in time, through system analysis, find out the cause of the fault, master the method of troubleshooting, restore the technical state of endoscopic equipment is very important.
  内窥镜设备送水送气不顺畅是怎么回事?以上就是相关内容的讲解了。如果您对此还有疑问的话,不妨点击网址www.jiangrenyiliao.cn直接来联系我们进行咨询!
  Is endoscope equipment to send water to send air not smooth how to return a responsibility? The above is the explanation of relevant content. If you have any questions about this, please click on the website www.jiangrenyiliao.cn to contact us directly for consultation!
s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

鲁公网安备 37010402441281号