  内窥镜作为医疗与工业检测领域的关键设备,其精密光学系统与机械结构对维修工具提出严苛要求。维修过程需结合电子检测、光学调试及机械校准等多学科技术,使用专业化工具保障设备恢复原始性能。以下从功能维度解析内窥镜维修的核心工具及其应用场景。

  As a key equipment in the fields of medical and industrial testing, endoscopes have strict requirements for maintenance tools due to their precise optical systems and mechanical structures. The maintenance process requires a combination of multidisciplinary technologies such as electronic testing, optical debugging, and mechanical calibration, and the use of specialized tools to ensure that the equipment is restored to its original performance. The following analyzes the core tools and their application scenarios for endoscopic maintenance from a functional perspective.

  一、光学系统检修工具

  1、 Optical system maintenance tool

  冷光源测试仪:

  Cold light source tester:

  用于检测氙灯或LED光源的色温、照度及光谱分布。设备通过积分球采集光线数据,可诊断光源老化程度,当色温偏差超过±500K或照度衰减至初始值70%以下时,需更换灯组模块。

  Used to detect the color temperature, illuminance, and spectral distribution of xenon lamps or LED light sources. The device collects light data through an integrating sphere to diagnose the degree of aging of the light source. When the color temperature deviation exceeds ± 500K or the illuminance attenuates to below 70% of the initial value, the lamp module needs to be replaced.

  光纤导光束检测仪:

  Fiber optic guided beam detector:

  采用光功率计测量导光束传输效率,正常值应≥85%。对于弯曲半径过小或受压变形的导光束,可通过显微镜观察纤芯断裂情况,断裂点超过3处即需整体更换。

  Using an optical power meter to measure the transmission efficiency of the guide beam, the normal value should be ≥ 85%. For guide beams with a bending radius that is too small or deformed under pressure, the fiber core fracture can be observed under a microscope, and if there are more than 3 fracture points, they need to be replaced as a whole.

  镜面擦拭套装:

  Mirror wiping kit:

  包含异丙醇清洗剂、无尘棉签与镜头纸,用于清除物镜、目镜表面的油污与划痕。对于顽固污渍,需使用CO?雪清洗机进行非接触式清洁,避免损伤镀膜层。

  Contains isopropanol cleaning agent, dust-free cotton swabs, and lens paper, used to remove oil stains and scratches on the surface of objective lenses and eyepieces. For stubborn stains, a CO snow cleaner should be used for non-contact cleaning to avoid damaging the coating layer.

  二、电子系统诊断设备

  2、 Electronic system diagnostic equipment

  示波器与逻辑分析仪:

  Oscilloscope and Logic Analyzer:

  联合使用可捕获图像传感器输出的LVDS信号波形,通过眼图分析判断信号完整性。当上升沿时间超过1ns或噪声容限低于200mV时,需检查柔性线路板焊接质量。

  Combine the captured LVDS signal waveform output by the image sensor and determine signal integrity through eye diagram analysis. When the rising edge time exceeds 1ns or the noise tolerance is below 200mV, the welding quality of the flexible circuit board needs to be checked.

20200426035244690

  CCD/CMOS测试卡:

  CCD/CMOS test card:

  生成标准分辨率图卡与灰阶卡,配合亮度计检测成像单元的MTF(调制传递函数)。若中心区域MTF@50lp/mm低于30%,需重新调整传感器与镜头的对焦精度。

  Generate standard resolution image cards and grayscale cards, and use a brightness meter to detect the MTF (Modulation Transfer Function) of the imaging unit. If the central area MTF@50lp /If the mm is less than 30%, the focusing accuracy of the sensor and lens needs to be readjusted.

  静电放电模拟器:

  Electrostatic discharge simulator:

  模拟人体8kV接触放电与15kV空气放电场景,验证主机电路的ESD防护能力。关键接口需通过IEC 61000-4-2四级测试标准,确保医疗环境下的使用安全性。

  Simulate human 8kV contact discharge and 15kV air discharge scenarios to verify the ESD protection capability of the host circuit. Key interfaces must pass the IEC 61000-4-2 Level 4 testing standard to ensure safety in medical environments.

  三、机械结构维修器具

  3、 Mechanical structure maintenance equipment

  内窥镜角度调节器:

  Endoscope angle adjuster:

  采用六轴力传感器与伺服电机系统,可精确复现弯曲部的蛇形运动。通过捕捉每个关节的扭矩曲线,诊断钢丝绳断裂或滑轮磨损故障,角度偏差超过5°即需维修。

  By using a six axis force sensor and servo motor system, the serpentine motion of the bending part can be accurately reproduced. By capturing the torque curve of each joint, diagnose faults such as wire rope breakage or pulley wear, and repair if the angle deviation exceeds 5 °.

  激光对中仪:

  Laser centering device:

  用于校准插入管的直线度,测量精度达0.01mm/m。对于直径8mm以上的工业内窥镜,弯曲段直线度误差需控制在0.5mm以内,避免检测时产生视觉盲区。

  Used to calibrate the straightness of the insertion tube, with a measurement accuracy of 0.01mm/m. For industrial endoscopes with a diameter of over 8mm, the straightness error of the curved section should be controlled within 0.5mm to avoid visual blind spots during inspection.

  密封性测试装置:

  Sealing testing device:

  通过正压(50kPa)与负压(-30kPa)双向检测,确认先端部防水等级。使用荧光检漏剂浸泡后,UV灯照射下无泄漏点方可重新封装,确保设备满足IP67防护要求。

  Confirm the waterproof level of the tip by bidirectional detection of positive pressure (50kPa) and negative pressure (-30kPa). After soaking in fluorescent leak detector, the equipment can only be repackaged after there are no leakage points under UV light irradiation to ensure that it meets IP67 protection requirements.

  四、专用校准与软件工具

  4、 Specialized calibration and software tools

  几何畸变校正卡:

  Geometric distortion correction card:

  印制标准网格图案,配合图像处理算法修正镜头畸变。医疗内窥镜需将畸变率控制在10%以内,工业检测设备则要求≤2%,保障测量数据的准确性。

  Print standard grid patterns and use image processing algorithms to correct lens distortion. Medical endoscopes need to control the distortion rate within 10%, while industrial testing equipment requires ≤ 2% to ensure the accuracy of measurement data.

  白平衡测试卡:

  White Balance Test Card:

  提供24色标准色块,通过光谱仪采集数据生成校正矩阵。在4000K色温环境下,色温误差需小于±200K,确保不同光源条件下的色彩还原一致性。

  Provide 24 standard color blocks, collect data through a spectrometer to generate a calibration matrix. In a 4000K color temperature environment, the color temperature error should be less than ± 200K to ensure consistency in color reproduction under different light source conditions.

  固件烧录器:

  Firmware burner:

  支持JTAG与SWD协议,可升级主机MCU与FPGA程序。对于具备图像增强功能的内窥镜,需定期更新降噪算法,提升低照度环境下的成像清晰度。

  Supports JTAG and SWD protocols, and can upgrade host MCU and FPGA programs. For endoscopes with image enhancement capabilities, it is necessary to regularly update noise reduction algorithms to improve imaging clarity in low light environments.

  内窥镜设备维修需构建光学、电子、机械三维检测体系,工具选型直接影响维修质量。随着4K成像与AI辅助诊断技术的发展,维修工具正向高精度、集成化方向演进,例如结合机器视觉的自动对焦校准台,已将维修效率提升40%。未来,模块化维修工具包将成为主流,助力工程师快速定位并解决复杂故障。

  The maintenance of endoscopic equipment requires the construction of an optical, electronic, and mechanical three-dimensional detection system, and the selection of tools directly affects the quality of maintenance. With the development of 4K imaging and AI assisted diagnostic technology, maintenance tools are evolving towards high precision and integration. For example, the automatic focus calibration table combined with machine vision has increased maintenance efficiency by 40%. In the future, modular maintenance toolkits will become mainstream, helping engineers quickly locate and solve complex faults.

  本文由内窥镜设备维修友情奉献.更多有关的知识请点击:http://www.jiangrenyiliao.cn我们将会对您提出的疑问进行详细的解答,欢迎您登录网站留言.

  This article is a friendly contribution from the maintenance of endoscopic equipment For more information, please click: http://www.jiangrenyiliao.cn We will provide detailed answers to your questions. You are welcome to log in to our website and leave a message

s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

备案号:鲁ICP备2023027194号-1    鲁公网安备 37010402441281号