硬式内窥镜的结构及故障

来源:http://www.jiangrenyiliao.cn/ 发布时间:2024-02-22 浏览量:0

内窥镜是用于通过进入人体外部成像,检查人体器官和组织病变的器械。临床上按照形态可以分为硬式内窥镜、软式内窥镜,按照用途可以分为鼻窦镜、腹腔镜、椎间孔镜等,按照角度可以分为0度镜、30度镜、70度镜、120度镜等。

Endoscope is an instrument used to examine lesions in human organs and tissues by entering the external body for imaging. In clinical practice, endoscopes can be divided into hard endoscopes and soft endoscopes according to their shape. They can be used for different purposes, such as sinusoscopes, laparoscopes, and intervertebral foramen endoscopes. They can be used for angles, such as 0 degree endoscopes, 30 degree endoscopes, 70 degree endoscopes, and 120 degree endoscopes.

硬式内窥镜的结构如下图,主要包括物镜、棒镜或棒镜组、目镜、特种不锈钢管等。

20200426035244690.jpg

The structure of a rigid endoscope is shown in the figure below, mainly including an objective lens, rod lens or rod lens group, eyepiece, special stainless steel tube, etc.

一般来讲,硬式内窥镜在出厂时都会做一定的测试,比如渗漏测试、震动测试等,出现故障比较多的是人为故障,比如不适当的使用(与刨削器械接触、激光碎石时激光打在镜管上),不适当的(超声清洗)。

Generally speaking, rigid endoscopes undergo certain tests before leaving the factory, such as leakage testing, vibration testing, etc. The most common faults are human errors, such as improper use (contact with planing instruments, laser hitting the endoscope tube during laser lithotripsy), and improper disinfection (ultrasonic cleaning).

常见故障包括图像模糊、照明亮度下降、图像缺角、镜管弯曲凹陷、器械管堵塞等,拆卸检查会发现原因可为盖玻璃损坏、导光束损坏、棒镜损坏等。

Common faults include blurred images, decreased lighting brightness, missing corners in images, bent and concave mirror tubes, and blocked instrument tubes. Upon disassembly and inspection, it can be found that the causes include damaged cover glass, damaged guide beams, and damaged rod mirrors.

本文由内窥镜设备维修友情奉献.更多有关的知识请点击:http://www.jiangrenyiliao.cn真诚的态度.为您提供为的服务.更多有关的知识我们将会陆续向大家奉献.敬请期待

This article is dedicated to the maintenance of endoscopic equipment. For more information, please click: http://www.jiangrenyiliao.cn Sincere attitude. We will provide you with comprehensive services. We will gradually contribute more relevant knowledge to everyone. Stay tuned

s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

鲁公网安备 37010402441281号