内窥镜的故障出在哪你知道吗?

来源:http://www.jiangrenyiliao.cn/ 发布时间:2021-11-30 浏览量:0

内窥镜分为硬镜和软镜,硬镜,一般使用在外科领域,插入管大多由不锈钢材料组成,也有前部可弯曲的硬镜,包括腹腔镜、鼻窦镜,前列腺电切镜、输尿管镜及宫腔镜等 。
Endoscope is divided into hard mirror and soft mirror, hard mirror, commonly used in surgical field, insert tube mostly by stainless steel material composition, also have front can bend hard mirror, include celioscope, nose sinuses mirror, prostate electrocision mirror, ureteroscope and hysteroscope to wait.
软镜,内科领域比较多见,如肠胃镜、十二指肠镜、喉镜、气管镜、插管镜及输尿管肾盂镜等。
Soft endoscopy, medical fields more common, such as gastroscope, duodenoscope, laryngoscope, tracheoscope, intubation and Ureteropelvic Mirror and so on.
但是,在使用的过程中,内窥镜难免会出现这样那样的故障,一般它的故障出在哪儿,今天就让匠仁医疗内窥镜设备维修的小团队来给大家说一下。
However, in the use of the process, the endoscope will inevitably have this kind of failure, it is generally where the failure, today let artisan medical endoscope equipment repair team to tell you.
一般故障会出现以下几个方面:
Common failures include the following:
显示器没有图像显示
为了确保图象主机和显示器已接通,图象主机和显示器的电源开关指示灯是否亮,如不亮,则需进行保险及供电检查,检查图象主机与显示器的连线、 IN和 OUT接口是否连接。在具有多种视频信号源选择器的显示器中,选择合适的视频信号。查看显示器的相应设置参数,将亮度、颜色、对比度默认设为默认,确保摄像机的连接电缆固定在图像主机上。在图象主机和显示器之间更换视频电缆,排除可能的电缆损坏。
Display no image display in order to ensure that the image host and the display are connected, whether the power switch indicator light of the image host and the display is on or not, if it is not, a power supply check should be carried out, check the connection between the image host and the Monitor, and the IN and OUT interfaces. In a display with a variety of video signal source selectors, select the appropriate video signal. Check the display settings, set the brightness, color, contrast to the default, to ensure that the camera cable fixed in the image host. Replace the video cable between the image host and the Monitor to eliminate possible cable damage.
监视
错误的图像颜色
错误的图象颜色要求 WB重新校正。先确定 RGB或 YPbPr接口没有接线错误,显示参数确定,主机参数确认,选择其它视频通道进行测试,进行 COLOR BAR测试。检查设定菜单的字体和颜色是否正常,如果正常,但内视镜图像不正常,基本上是内视镜或摄像头故障。
Monitor the wrong image color the wrong image color requires WB recalibration. First determine RGB or YPbPr interface no wiring error, display parameters determined, host parameters confirmed, select other video channels for testing, COLOR BAR testing. Check that the font and color of the settings menu are normal, if so, but the endoscopic image is not normal, basically an endoscopic or camera failure.
图象干扰
发生干扰时应检查使用的高频、强电的接地是否有问题,外部设备的信号线是否有问题。
If image interference occurs, check the grounding of the high frequency and high current used and the signal line of the peripheral equipment.
好了今天匠仁医疗内窥镜设备维修给大家先介绍到这里,相信你看过后,以后会注意内窥镜的使用和维护了吧,接下来关于内窥镜的其它问题,关注官网http://www.jiangrenyiliao.cn/,我们继续更新。
Okay, today, artisan medical endoscopic equipment maintenance to everyone first introduced here, I believe that after you have seen, you will pay attention to the use and maintenance of the endoscope, right? Next on the other issues of the endoscope, attention to the official website, we continue to update.
 
 
s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

鲁公网安备 37010402441281号